Size:100mm(L)x55mm(W)x32mm(D)
Cutting Size: 75mm(L)x55mm(W)x32mm(D)
Temperature measurement range: -50 ~ + 110 °C
Temperature Control Range: -19~99°C
Temperature measuring accuracy: ±0.3 °C
Resolution: 1 °C
Accuracy: 1 °C
Temperature measuring probe: NTC10K / B3435
Power supply voltage:DC 12V
Display colors: red yellow
The output type: Relay 10A / DC 12V, the load needs to connect with a independent power supply
F-1: Intermittent work Left : Start working setting(Minute) Right: Stop working setting(Minute )
F-2: Time off Left: hour Right: Minute Max setting: 99 hours 59 minutes
F-3: Time on Left: hour Right: Minute Max setting: 99 hours 59 minutes
Size
Instruction
If the temperature is between the start and stop temperature, the relay is on.
It is off when the temperature reach the stop temperature
SET – function switch/ ON/OFF
At on state, long press SET for 3 seconds to turn on the controller. If it is off when power off, it will stay off when power on.
At off state, press SET to turn on, if it is on when power off. It will stay on when power on.
At working state, press SET to choose F-1, F-2, F-3( These are attached functions , it is nothing to do with the controller setting, set it as you need )
F-1 | Intermittent work Left : Start working setting(Minute) Right: Stop working setting(Minute ) |
F-2 | Time off Left: hour Right: Minute Max setting: 99 hours 59 minutes |
F-3 | Time on Left: hour Right: Minute Max setting: 99 hours 59 minutes |
Temperature Calbration
Unplug the controller, press SET, enter temperature calibration function, display - -000- - , you can add/subtract the temperature base on the temperature before calibration. Max Range -9.9°C~99°C, after calibrating, current temperature=before calibrating temperature + calibration value
Self test function
Both Press the buttons “up” and ” down ”, and power on, then it will enter self-test function
Reset
Both Press the buttons “up” and ” down ”, and power on, turn on the controller , then it will display 88-888-88, the buzzer beeps, then reset done.
Heating Cooling mode
Start temperature < stop temperature = Heating Mode
Start temperature > stop temperature = Cooling Mode